LTSWITCH GEAR PANELS

MV Panel

MV Panel Type Freestanding cubicle compartmentalized – Form 4
Sheet Steel 16 SWG / 1.6 mm CRCA for enclosure outer shell
14 SWG / 2.0 mm CRCA for panel doors
Surface finish Pretreated 7-tank process
Powder coated or spray painted – poly urethane
Bus bar supports SMC/DMC insulators
Partition 3.2 mm FRP sheet
Shrouding 1.6 mm FRP sheet
Incomer Up to 3200 A, TPN/4P Air circuit breaker – 65 k A
Out going As per customer requirement – Fuse switch unit or MCCB -35 k A
Interlocking 2 lock + 1 key

TOP


Sub Switch Board

Sub Switch Board

Sub Switch Board Type Freestanding cubicle compartmentalized – Form 4
Sheet Steel 16 SWG / 1.6 mm CRCA for enclosure outer shell
14 SWG / 2.0 mm CRCA for panel doors
Surface finish Pretreated 7-tank process
Powder coated or spray painted – poly urethane
Bus bar supports SMC/DMC insulators
Partition 3.2 mm FRP sheet
Shrouding 1.6 mm FRP sheet
Incomer Up to 800 A, TPN, Fuse switch unit or MCCB– 35 k A
Out going As per customer requirement – Fuse switch unit or MCCB -25 k A

TOP


Motor Control Center – Option I

Motor Control Center

Motor Control Center Type Freestanding cubicle compartmentalized – Form 4
Sheet Steel 16 SWG / 1.6 mm CRCA for enclosure outer shell
14 SWG / 2.0 mm CRCA for panel doors
Surface finish Pretreated 7-tank process
Powder coated or spray painted – poly urethane
Bus bar supports SMC/DMC insulators
Partition 3.2 mm FRP sheet
Shrouding 1.6 mm FRP sheet
Incomer Up to 800 A, TPN, Fuse switch unit or MCCB– 35 k A
Out going As per customer requirement – Fuse switch unit or MCCB -25 k A as incomer for individual starter OR
Motor protection circuit breakers – 50 / 100 k A
Controls Illuminated push buttons with LED for on and off
Indications – LED pilot lamps for power on, motor on and trip

TOP

Motor Control Center – Option II

Motor Control Center

Type Desk type Console – Form – 1/2
Sheet Steel 16 SWG / 1.6 mm CRCA for enclosure outer shell
14 SWG / 2.0 mm CRCA for panel doors
Surface finish Pretreated 7-tank process
Powder coated or spray painted – poly urethane
Bus bar supports SMC/DMC insulators
Partition 3.2 mm FRP sheet
Shrouding 1.6 mm FRP sheet
Incomer Up to 400 A, TPN, Fuse switch unit or MCCB– 35 k A
Out going As per customer requirement – Fuse switch unit or MCCB -25 k A as incomer for individual starter OR
Motor protection circuit breakers – 50 / 100 k A

Controls Illuminated push buttons with LED for on and off
Indications – LED pilot lamps for power on, motor on and trip

TOP


Fuse Distribution Boards

Fuse Distribution Boards

TOP


Automatic Power Factor Correction Panel

Automatic Power Factor Correction Panel


Go Top

 

© Copyright All Right Reserved hitec system Site Designed by Nissi Infotech